TriOS NICO plus UV Nitrate Sensor
Features
- Internal compensation for temperature, turbidity, and organic substances
- RS-485 Modbus RTU output for integration with data collection platforms
- Optional W55 V2 wiper cleans optics & reduces maintenance intervals
- Expedited repair and warranty service
- Lifetime technical support
- More
The new TriOS NICO plus not only offers the parameters NO3-N, NO3, NOx-N and NOx previously known from NICO, but has now been expanded to include numerous additional parameters. These include UVT254, UVT254n, SAK254, CSBeq, BSBeq, TOCeq, DOCeq, turbidity and TSSeq.
An internal temperature correction additionally increases the stability of the measured values. Equipped with the innovative G2 interface with web browser configuration and internal data logger, NICO plus has features that are significantly above the currently available devices on the market, in combination with an attractive price.
The sensor can be easily integrated into existing process control systems and external data loggers using the native RS-485 Modbus RTU output, and the optional W55 V2 wiper reduces maintenance intervals by cleaning the optics before each measurement.
|
Light Source
|
Xenon flash lamp
|
|
|
Detector
|
4 photo diodes + filter
|
|
|
Measurement Principle
|
Attenuation
|
|
|
Optical Path
|
0,3 mm, 1 mm, 2 mm, 5 mm, 10 mm, 20 mm, 50 mm
|
|
|
|
||
|
Parameter
|
NO3-N, NO3, NOx-N, NOx, UVT254, UVT254n, SAC254, CODeq, BODeq, TOCeq, DOCeq, Turb, TSSeq
|
|
|
Measurement Range
|
See measurement ranges
|
|
|
Measurement Accuracy
|
± (5 % + 2-fold detection limit)
|
|
|
Turbidity Compensation
|
Yes
|
|
|
Data Logger
|
~ 2 GB
|
|
|
T100 Response Time
|
20 s
|
|
|
Measurement Interval
|
≥ 10 s
|
|
|
|
||
|
Housing Material
|
Stainless steel (1.4571/1.4404) or titanium (3.7035)
|
|
|
Dimensions (L x Ø)
|
~ 470 mm x 48 mm (10 mm path)
|
~ 18.5“ x 1.9“ (with10 mm path)
|
|
Weight (Stainless Steel)
|
~ 3 kg
|
~ 6.6 lbs
|
|
|
||
|
Digital Interface
|
Ethernet (TCP/IP), RS-485 (Modbus RTU)
|
|
|
Power Consumption
|
≤ 7 W
|
|
|
Power Supply
|
12...24 VDC (± 10 %)
|
|
|
|
||
|
Maintenance Effort
|
≤ 0.5 h/month (typical)
|
|
|
Calibration/Maintenance Interval
|
24 months
|
|
|
System Compatibility
|
Modbus RTU
|
|
|
Warranty
|
1 year (EU: 2 years)
|
USA: 2 years
|
|
|
||
|
Max. Pressure with SubConn
|
30 bar
|
~ 435 psig
|
|
Max. Pressure with Fixed Cable
|
3 bar
|
~ 43.5 psig
|
|
Max. Pressure in FlowCell
|
1 bar, 2...4 L/min
|
~ 14.5 psig at 0.5 to 1.0 gpm
|
|
Protection Type
|
IP68
|
NEMA 6P
|
|
|
||
|
Sample Temperature
|
+2...+40 °C
|
~ +36 °F to +104 °F
|
|
Ambient Temperature
|
+2...+40 °C
|
~ +36 °F to +104 °F
|
|
Storage Temperature
|
-20...+80 °C
|
~ -4 °F to +176 °F
|
|
Inflow Velocity
|
0,1...10 m/s
|
~ 0.33 to 33 fps
|
In The News
Great Lakes Research Center: Designing Targeted Monitoring Solutions
According to the National Oceanic and Atmospheric Administration ( NOAA ), the Great Lakes have more miles of coastline than the contiguous Atlantic and Pacific coasts combined and contain 20 percent of the world's freshwater, making it a critical region to protect and conserve. Continuous monitoring and data-informed resource management are key components of managing waters in the region. Hayden Henderson, a research engineer with the Great Lakes Research Center (GLRC), designs and deploys monitoring platforms throughout the Great Lakes. With a background in environmental engineering, Henderson enjoyed the challenge of creating systems and making them work to obtain difficult, remote measurements.
Testing CO2 Removal Strategies in the Pacific Northwest
The ocean plays a key role in carbon dioxide (CO2) removal and storage, also known as carbon sequestration. However, with increasing emissions, a large amount of CO2 escapes into the atmosphere, worsening climate change and leading to increases in surface temperatures. In order to mitigate some of these impacts, researchers like Ally Savoie at the Pacific Northwest National Laboratory (PNNL) are working hard to identify ways to safely improve the CO2 removal and storage capabilities in the ocean. Savoie started her career at Wright State University , where she worked in Silvia Newell’s lab examining biogeochemical cycling of nutrients in a river system. From there, she decided to pursue a master’s in marine science at the University of Southern Mississippi with Dr.
Smart Buoys Advance Climate Monitoring in Swiss Lakes
Lakes are sentinels of climate change . Globally, they are warming at an unprecedented but uneven rate, and in many places they also face direct human pressure, including from agriculture and recreation. In the Alps, scientists generally agree that climate change is of particular threat to remote lakes , where more pronounced warming threatens fragile ecosystems. Alpine Lakes in a Changing Climate Matteo Tonellotto is part of the team at the Environmental Observatory of the Italian-speaking region of Switzerland (OASI)–a multidisciplinary team of scientists, IT specialists, and chemical laboratory technicians committed to collecting, managing, and integrating high-quality environmental data.
Connecting with Nature in Real-Time at the Abernathy Field Station
Just five miles away from Washington and Jefferson (W&J) College is the 57-acre Abernathy Field Station . Generously donated by the Abernathy family in 2017, the field station has served as an outdoor lab to hundreds of undergraduate students over the years. Many classes use the Abernathy Field Station every week. For example, in BIO 111, students spend 15 weeks conducting their own research at the field station using a combination of sampling, field observations, and real-time environmental data, giving them a look into the world of science and a closer relationship with nature. “We like to start the students in the research process in their first Biology class.