HOBO UX100 Temp/RH Loggers

The Onset HOBO UX100 temperature and humidity series data loggers track temperature and relative humidity in indoor environments.

Features

  • Large memory capacity
  • Visual high & low alarm thresholds
  • User-replaceable RH sensors
Starting At $115.00
Stock Check Availability  

Overview
The HOBO UX100 temperature and humidity series data loggers track temperature and relative humidity in indoor environments. Records temperature in indoor environments. Ideal for monitoring occupant comfort in office buildings, tracking warehouse storage conditions, and logging temperature trends in server rooms.

Design
HOBO UX100 Series offers a dramatic price/performance advantage over competitive products by delivering higher accuracy, larger measurement capacity, and more LCD display features to make environmental data collection faster and easier than ever. The loggers provide a variety of features to reduce deployment time and offer new logging modes for recording and displaying more detailed data without extensive post-processing or memory use.

Temperature Sensor
Range: -20° to 70°C (-4° to 158°F)
Accuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F)
Resolution: 0.024°C at 25°C (0.04°F at 77°F)
Response time: 8 minutes in air moving 1 m/s (2.2 mph)
Drift: <0.1°C (0.18°F) per year

Data Logger
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button
Time accuracy: ±1 minute per month at 25°C (77°F)
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater 
Battery type: One 3V CR2032 lithium battery ​
Memory: 128 KB (84,650 measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: 20 seconds
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight: 23 g (0.81 oz)
Environmental rating: IP50

  • HOBO UX100-001 Temp Data Logger
  • Command™ strip
  • Double-sided tape
  • Hook & loop strap
Questions & Answers
No Questions
Did you find what you were looking for?

Select Options

  Products 0 Item Selected
Image
Part #
Description
Price
Stock
Quantity
HOBO UX100 Temp/RH Loggers
UX100-001
HOBO UX100 internal temperature logger
$115.00
Check Availability  
HOBO UX100 Temp/RH Loggers
UX100-003
HOBO UX100 internal temperature/relative humidity logger, 3.5% accuracy
$135.00
Check Availability  
HOBO UX100 Temp/RH Loggers
UX100-011A
HOBO UX100 internal temperature/relative humidity logger, 2.5% accuracy
$175.00
Check Availability  
  Accessories 0 Item Selected
Notice: At least 1 product is not available to purchase online
×
Multiple Products

have been added to your cart

There are items in your cart.

Cart Subtotal: $xxx.xx

Go to Checkout

In The News

Testing CO2 Removal Strategies in the Pacific Northwest

The ocean plays a key role in carbon dioxide (CO2) removal and storage, also known as carbon sequestration. However, with increasing emissions, a large amount of CO2 escapes into the atmosphere, worsening climate change and leading to increases in surface temperatures. In order to mitigate some of these impacts, researchers like Ally Savoie at the Pacific Northwest National Laboratory (PNNL) are working hard to identify ways to safely improve the CO2 removal and storage capabilities in the ocean. Savoie started her career at Wright State University , where she worked in Silvia Newell’s lab examining biogeochemical cycling of nutrients in a river system. From there, she decided to pursue a master’s in marine science at the University of Southern Mississippi with Dr.

Smart Buoys Advance Climate Monitoring in Swiss Lakes

Lakes are sentinels of climate change . Globally, they are warming at an unprecedented but uneven rate, and in many places they also face direct human pressure, including from agriculture and recreation. In the Alps, scientists generally agree that climate change is of particular threat to remote lakes , where more pronounced warming threatens fragile ecosystems. Alpine Lakes in a Changing Climate Matteo Tonellotto is part of the team at the Environmental Observatory of the Italian-speaking region of Switzerland (OASI)–a multidisciplinary team of scientists, IT specialists, and chemical laboratory technicians committed to collecting, managing, and integrating high-quality environmental data.

Connecting with Nature in Real-Time at the Abernathy Field Station

Just five miles away from Washington and Jefferson (W&amp;J) College is the 57-acre Abernathy Field Station . Generously donated by the Abernathy family in 2017, the field station has served as an outdoor lab to hundreds of undergraduate students over the years. Many classes use the Abernathy Field Station every week. For example, in BIO 111, students spend 15 weeks conducting their own research at the field station using a combination of sampling, field observations, and real-time environmental data, giving them a look into the world of science and a closer relationship with nature. “We like to start the students in the research process in their first Biology class.

Riding the Renewable Wave: Testing Wave Energy Converters at Oregon’s PacWave Site

Seven miles off Oregon’s weather-beaten coastline, the world’s biggest wave power testing facility, PacWave, is primed to put the latest renewable energy technology to the test. “There is a huge amount of energy that is not harvested in the ocean,” states the team at Oregon State University involved in the PacWave project. When it comes to harnessing the power of the waves, “It's exciting because it [wave power] is a non-polluting, non-carbon burning technology,” the team says. Wave Power The U.S. Energy Information Administration explains that tidal energy harnesses the flow of seawater in depth under the gravitational forces exerted by the sun and moon–the drivers of tides–while wave energy derives from the kinetic energy of wind-blown surface waves.