Hach Intellical PHC101 Laboratory Gel Filled pH Electrodes

The Hach Intellical PHC101 Laboratory Gel Filled pH Electrode is a digital combination pH electrode with a built-in temperature sensor. 

Features

  • Provides fast, stable response in wastewater applications
  • Probe alerts the user when re-calibration is needed
  • Probe can be moved between meters without the need to re-calibrate or re-enter measurement settings
Starting At $453.00
Stock Drop Ships From Manufacturer  

Overview
The Hach Intellical PHC101 Laboratory Gel Filled pH Electrode is a digital combination pH electrode with a built-in temperature sensor. The Hach PHC101 has low maintenance needs thanks to a non-refillable gel-filled single open reference junction. The laboratory version of this pH electrode is shockproof, with its epoxy plastic body protecting down to the glass bulb sensing element.

Applications
The electrode is available with a 3 or 1m cable. The PHC101 electrode is ideal for measuring pH in wastewater, drinking water and general aqueous applications. The PHC101 is not suitable for use with organic solvents or samples with pH less than 2.

Accuracy: ±0.02 pH
Application: Clean & Dirty Samples
Cable Length: 1 m (3.28 ft)
Electrode Type: Non-Refillable Gel Reference Element
Junction: Open Junction
Kit?: No
Length: 175 mm (6.89 in.)
Method Type: Field: Non-Refillable Gel Reference Element
Parameter: pH
Probe Type: Standard
Product Kit: Model: PHC101
Accessories Included: None
Range: 2 - 14 pH
Reference Type: Ag/AgCl
Resolution: 0.001/0.01/0.1
Sample depth: 20 mm (0.79 in.)
Sensor material: Epoxy
Sensor Type: pH Glass
Sodium (Alkalinity) error: -0.6 pH at pH 12.6 in 1 M NaOH
Special Features: Double junction reference
Temperature Accuracy: ±0.3 °C (±0.54 °F)
Temperature Range: 0 - 50 °C (32 - 122 °F)
Temperature Resolution: 0.1 °C (0.18 °F)
Test requirements: Parameter Needed: pH
Minimum Sample Depth (mm): 20
Thermistor: ATC
Warranty: 6 months
Weight: 0.1 kg
What's included?: IntelliCAL PHC101 Laboratory pH electrode with storage soaker bottle, 1 m cable, Test certificate, and Basic User Manual.
Questions & Answers
No Questions
Did you find what you were looking for?

Select Options

  Products 0 Item Selected
Image
Part #
Description
Price
Stock
Quantity
Hach Intellical PHC101 Laboratory Gel Filled pH Electrodes
PHC10101
Intellical PHC101 Laboratory Low Maintenance Gel Filled pH Electrode, 1m Cable
$453.00
Drop Ships From Manufacturer  
Hach Intellical PHC101 Gel Filled pH Electrodes
PHC10103
Intellical PHC101 Laboratory Low Maintenance Gel Filled pH Electrode, 3m Cable
$497.00
Drop Ships From Manufacturer  
Notice: At least 1 product is not available to purchase online
×
Multiple Products

have been added to your cart

There are items in your cart.

Cart Subtotal: $xxx.xx

Go to Checkout

In The News

Testing CO2 Removal Strategies in the Pacific Northwest

The ocean plays a key role in carbon dioxide (CO2) removal and storage, also known as carbon sequestration. However, with increasing emissions, a large amount of CO2 escapes into the atmosphere, worsening climate change and leading to increases in surface temperatures. In order to mitigate some of these impacts, researchers like Ally Savoie at the Pacific Northwest National Laboratory (PNNL) are working hard to identify ways to safely improve the CO2 removal and storage capabilities in the ocean. Savoie started her career at Wright State University , where she worked in Silvia Newell’s lab examining biogeochemical cycling of nutrients in a river system. From there, she decided to pursue a master’s in marine science at the University of Southern Mississippi with Dr.

Smart Buoys Advance Climate Monitoring in Swiss Lakes

Lakes are sentinels of climate change . Globally, they are warming at an unprecedented but uneven rate, and in many places they also face direct human pressure, including from agriculture and recreation. In the Alps, scientists generally agree that climate change is of particular threat to remote lakes , where more pronounced warming threatens fragile ecosystems. Alpine Lakes in a Changing Climate Matteo Tonellotto is part of the team at the Environmental Observatory of the Italian-speaking region of Switzerland (OASI)–a multidisciplinary team of scientists, IT specialists, and chemical laboratory technicians committed to collecting, managing, and integrating high-quality environmental data.

Connecting with Nature in Real-Time at the Abernathy Field Station

Just five miles away from Washington and Jefferson (W&J) College is the 57-acre Abernathy Field Station . Generously donated by the Abernathy family in 2017, the field station has served as an outdoor lab to hundreds of undergraduate students over the years. Many classes use the Abernathy Field Station every week. For example, in BIO 111, students spend 15 weeks conducting their own research at the field station using a combination of sampling, field observations, and real-time environmental data, giving them a look into the world of science and a closer relationship with nature. “We like to start the students in the research process in their first Biology class.

Riding the Renewable Wave: Testing Wave Energy Converters at Oregon’s PacWave Site

Seven miles off Oregon’s weather-beaten coastline, the world’s biggest wave power testing facility, PacWave, is primed to put the latest renewable energy technology to the test. “There is a huge amount of energy that is not harvested in the ocean,” states the team at Oregon State University involved in the PacWave project. When it comes to harnessing the power of the waves, “It's exciting because it [wave power] is a non-polluting, non-carbon burning technology,” the team says. Wave Power The U.S. Energy Information Administration explains that tidal energy harnesses the flow of seawater in depth under the gravitational forces exerted by the sun and moon–the drivers of tides–while wave energy derives from the kinetic energy of wind-blown surface waves.