Hach DR1900 Portable Spectrophotometer
The Hach DR1900 portable spectrophotometer is perfect for use in the field because of the lightweight and compact design.
Features
- Carry anywhere due to a thoughtful, compact design
- Ensure accuracy in the field
- Clear, easy-to-use interface
- Free ground shipping
- Expedited repair and warranty service
- Lifetime technical support
- More
Overview
The Hach DR1900 portable spectrophotometer excels in the field because of the lightweight and compact design. The DR1900 is built for rugged conditions, and it’s flexible, --accepting the widest range of vial sizes.
Built with field use in mind, the DR1900 has a large, clear screen and a simple user interface that makes testing easier than ever in even the most demanding conditions.
Advanced Testing
Easy to hold, and operate, the compact DR1900 is a valuable tool for your field technicians. Underneath the rugged exterior, the DR1900 has the largest number,-- over 220-- of the most commonly tested preprogrammed methods already built in. You can also use the easy-to-use interface to create your own methods.
Tests are performed with a wavelength range of 340 to 800 nm which make this a field instrument you can use to find results typically only seen in laboratory instruments.
Notes
Reagents listed below are EPA approved. For the full list of reagents and methods that can be used with the DR1900, refer to the Hach Methods Quick Reference Guide
TNTplus vial test evaluation possible, but without barcode identification & 10 fold measurement and outlier elimination.
- Battery Life: 15 days (typical) @ 5 readings a day / 5 day week without backlight*
- Battery Requirements: 4, AA size alkali cells
- Cuvette Compatibility 2: 10 mm square / 1 inch square and 13 mm / 16 mm / 1 inch round
- Data Logger: 500 measured values (Result, Date, Time, Sample ID, User ID acc. to GLP)
- Detector: Silicon photodiode
- Dimensions (H x W x D): 98 mm x 178 mm x 267 mm
- Display: Graphical display 240 x 160 pixel (LCD, b/w, backlit)
- Enclosure Rating: IP67
- Interface: USB type Mini IP67 (with USB + Power Module)
- Mains Connection 2: 110 - 240 V / 50/60 Hz (* optional Module required. May not be available in all regions)
- Mains Connection 3: 4x NiMH rechargeable Battery (* optional Module required. May not be avaliable in all region)
- Operating Conditions: 10 - 40 °C (50 - 104 °F), max. 80 % relative humidity (non-condensing)
- Operating Humidity: Max. 80 % relative humidity (non-condensing)
- Operating Mode: Transmittance (%), Absorbance and Concentration
- Operating Temperature: 10 - 40 °C
- Optical System: Reference beam, spectral
- Photometric Accuracy: ± 0.003 Abs @ 0.0 - 0.5 Abs
- Photometric Linearity: < 0.5 % (0.5 - 2.0 Abs)
- Photometric Measuring Range: 0 - 3 Abs (wavelength range 340 - 800 nm)
- Power Module?: Yes
- Power Supply: 4 x AA size Alkaline
4x NiMH rechargeable Battery
Power supply: 110 - 240 V; 50/60 Hz - Region: US
- Reproducibility: ± 0.005 Abs (0 - 1 A)
- Sample Cell Compatibility: 13 / 16 mm and 1 inch round 10 x 10 mm 1 inch square adapter for round vials and 10x10mm
- Source Lamp: Xenon Flash
- Storage Conditions: -30 - 60 °C (-30 - 140 °F), max. 80 % relative humidity (non-condensing)
- Stray Light: < 0.5 %T at 340 nm with NaNO2
- Temperature Range: 0 - 50 °C (32 - 122 °F)
- User Interface Languages: English, French, German, Italian, Spanish, Portuguese, Bulgarian, Chinese, Czech, Danish, Dutch, Finnish, Greek, Hungarian, Japanese, Korean, Polish, Romanian, Russian, Slovenian, Swedish, Turkish
- User Programs: 50
- Warranty: 12 months
- Wavelength Accuracy: ± 2 nm (range 340 - 800nm)
- Wavelength Calibration: Automatic
- Wavelength Range: 340 - 800 nm
- Wavelength Selection: Automatic
- Weight: 1.5 kg
- What's included?: portable spectrometer, printed basic instrument manual, dust cover, 1-in. square matched glass sample cells, AA alkaline batteries 4/pk, a four-type vial adapter set, and a USB + Power module (LZV813).
* Backlight usage will decrease battery life.
- Portable spectrometer
- Printed basic instrument manual
- Dust cover
- 1-in. square matched glass sample cells
- AA alkaline batteries 4/pk
- Four-type vial adapter set
- USB + Power module (LZV813.99.00002)
In The News
Testing CO2 Removal Strategies in the Pacific Northwest
The ocean plays a key role in carbon dioxide (CO2) removal and storage, also known as carbon sequestration. However, with increasing emissions, a large amount of CO2 escapes into the atmosphere, worsening climate change and leading to increases in surface temperatures. In order to mitigate some of these impacts, researchers like Ally Savoie at the Pacific Northwest National Laboratory (PNNL) are working hard to identify ways to safely improve the CO2 removal and storage capabilities in the ocean. Savoie started her career at Wright State University , where she worked in Silvia Newell’s lab examining biogeochemical cycling of nutrients in a river system. From there, she decided to pursue a master’s in marine science at the University of Southern Mississippi with Dr.
Smart Buoys Advance Climate Monitoring in Swiss Lakes
Lakes are sentinels of climate change . Globally, they are warming at an unprecedented but uneven rate, and in many places they also face direct human pressure, including from agriculture and recreation. In the Alps, scientists generally agree that climate change is of particular threat to remote lakes , where more pronounced warming threatens fragile ecosystems. Alpine Lakes in a Changing Climate Matteo Tonellotto is part of the team at the Environmental Observatory of the Italian-speaking region of Switzerland (OASI)–a multidisciplinary team of scientists, IT specialists, and chemical laboratory technicians committed to collecting, managing, and integrating high-quality environmental data.
Connecting with Nature in Real-Time at the Abernathy Field Station
Just five miles away from Washington and Jefferson (W&J) College is the 57-acre Abernathy Field Station . Generously donated by the Abernathy family in 2017, the field station has served as an outdoor lab to hundreds of undergraduate students over the years. Many classes use the Abernathy Field Station every week. For example, in BIO 111, students spend 15 weeks conducting their own research at the field station using a combination of sampling, field observations, and real-time environmental data, giving them a look into the world of science and a closer relationship with nature. “We like to start the students in the research process in their first Biology class.
Riding the Renewable Wave: Testing Wave Energy Converters at Oregon’s PacWave Site
Seven miles off Oregon’s weather-beaten coastline, the world’s biggest wave power testing facility, PacWave, is primed to put the latest renewable energy technology to the test. “There is a huge amount of energy that is not harvested in the ocean,” states the team at Oregon State University involved in the PacWave project. When it comes to harnessing the power of the waves, “It's exciting because it [wave power] is a non-polluting, non-carbon burning technology,” the team says. Wave Power The U.S. Energy Information Administration explains that tidal energy harnesses the flow of seawater in depth under the gravitational forces exerted by the sun and moon–the drivers of tides–while wave energy derives from the kinetic energy of wind-blown surface waves.